SVV0.S10 VALVE SERIES
SAE Cartridge - 350 bar
NO Single Lock Pilot Operated
Poppet type
HYDRAULIC SYMBOL
Cross section
Cavity
SAE10
DESCRIPTION
A solenoid valve operated, 2-way 2-positions, normally open, piloted poppet type, screw-in cartridge valve. Typically used as a
blocking or load holding device for high pressure circuits. When the coil is de-energized, the SVV0.S10 allows flow from 1 to 2,
while flow from 2 to 1 is severely restricted. When the coil is energized the valve closes, blocking flow from 1 to 2. In this mode, flow
from 2 to 1 is allowed once the pressure overcomes the force of the solenoid. The rigid design using a 1-piece body contributes to
minimize the effect of eccentricities in cavity and provides great reliability. Low pressure drop thanks to optimized flow path.
TECHNICAL DATA
0,25 cm
3
/ min @ 30 bar
EXTERNAL COMPONENT TREATMENT
Zn/Fe - standard (96h)
Zn/Ni (720h) (Upon customer request)
MAXIMUM FLOW
80 l/min
MAXIMUM OPERATING PRESSURE
350 bar
WEIGHT
0,154 kg
SEAL KIT CODE
SK.032 and SK.027 (coil) (standard sealing NBR-BUNA-N)
OIL TESTING CONDITIONS
ISO VG 46 cSt
TECH. SPEC. FOR CHARACTERIZATION
see page 689
ORIENTATION
No restrictions
INSTALLATION TORQUE
65-75 Nm
FILTRATION
20/18/15 ISO 4406 (maximum filtration admitted)
VISCOSITIES
7,4 to 420 cSt
FLUIDS
Mineral - based or synthetics with lubricating properties
OIL TEMPERATURE RANGE
-30° C to 110° C
O-RING TEMPERATURE RANGE
-30° C to 110° C (standard sealing NBR - BUNA - N)
-35° C to 140° C (HNBR - Upon customer request)
-23° C to 225° C (FKM - Upon customer request)
Hex.27
MAXIMUM INTERNAL LEAKAGE
SWITCH ON TIME
70 ms
60 ms
SWITCH OFF TIME
85% of nominal
MINIMUM PULL-IN VOLTAGE
COIL
20,5 W (Upon customer request - for more details see page 593 - 603)
22 W (for more details see page 593 - 603)
S V V 0
.
ORDERING CODE
S 1 0 0
*
. .
* 0
*
Valve basic code
Size
Marking
0 = Standard factory marking.
Customized marking can be done
upon request.
FILTRATION
7/8-14 UNF with Ø15,87 nose
size
Model
code
Type of filter
N No filter
Customized filters can be done
upon request
Note
Note
Costumized nut can
be selected
SOLENOID Valves
Specifications may change without notice.
459 460
Rev. 1
SOLENOID Valves
Performance Limits
The performance chart illustrates flow handling capacity 1 to 2 (de-energized).
p/Q curves are recorded at TOil = 40°C and 46 cSt.
NOTE
De-Energized
461 462
SVV0.S10 GRAPHS
The performance chart illustrates flow handling capacity 1 to 2 (de-energized).
p/Q curves are recorded at TOil = 40°C and 46 cSt.
Rev. 1